Iris Management Suite
Technical Guide V1.7C 4/11/07
34
12 SIA Codes on ARC Serial Link
Polling Engines transmit Alarm Messages via the serial link to the ARC
according to the serial link emulation in use (Surguard or Radionics).
Messages received from IRIS diallers in Fast Format, Contact ID and SIA
formats are transmitted without modification, in the same way as if they had
been received by a standard PSTN receiver.
Messages generated internally by the Polling Engine to report Poll
Overdue/Restore or dialler interface Trouble/Restore use SIA event code
format messages. As an option a SIA text message is only semt. These are
as shown below:
EVENT SIA DATA
TYPE CODE
ZONE
NUMBER
TEXT MESSAGE
IRIS Dialler Polling Overdue YC 9001 POLLING Overdue
IRIS Dialler Polling OK YK 9001 POLLING Restore
IRIS ISDN Comms Trouble NT 9001 ISDN Comms Trouble
IRIS PSTN Comms Trouble NT 9002 PSTN Comms Trouble
IRIS Ethernet Comms
Trouble
NT 9004 ETHERNET Comms
Trouble
IRIS GSM/GPRS Comms
Trouble
NT 9003 GPRS Comms Trouble
IRIS Panel Interface Trouble NT 9006 PANEL Comms Trouble
IRIS Pin Input Trouble NT 9007 PIN INPUTS Trouble
IRIS ISDN Comms Restore NR 9001 ISDN Comms Restore
IRIS PSTN Comms Restore NR 9002 PSTN Comms Restore
IRIS Ethernet Comms
Restore
NR 9004 ETHERNET Comms
Restore
IRIS GSM/GPRS Comms
Restore
NR 9003 GPRS Comms Restore
IRIS Panel Interface
Restore
NR 9006 PANEL Comms Restore
IRIS Pin Input Restore NR 9007 PIN INPUTS Restore
Polling Engine IP Link
Trouble
NT 9102
Polling Engine IP Link
Restore
NR 9102
Komentarze do niniejszej Instrukcji